Getting Started with ELAM

Step by step to your first work instruction: flowchart, pick-to-light, screwdriver, question lists and verification in the assistant.

Quickstep version 1.1.1-r | Armbruster Engineering GmbH & Co. KG

This Quickstep is valid for software version 1.1.1-r.

Great care was taken in compiling the illustrations and texts. However, errors cannot be completely ruled out. Please note that Armbruster Engineering GmbH cannot accept any liability for this. We are very grateful for any notice of errors and suggestions for improvement.

Note: The screenshots in this guide show the German user interface. The language can be changed via the language selection in ELAM.

Note on terminology

  • This document uses the term “Pick-to-Light”. It is equivalent to the term “Pick-by-Light”.
  • TAF stands for “Teilarbeitsfolge” (sub-work sequence) and represents a work step in ELAM.

1. Introduction

ELAM is the worker assistance system from Armbruster Engineering. It guides the worker step by step through manual assembly, controls tools such as screwdrivers and records production data.

This document guides first-time users through setting up a work instruction, including the connection of a screwdriver and a pick-to-light module.

More detailed explanations can be found in the so-called “Quicksteps” at armbruster.de/downloads. Some content overlaps with this document.

2. Sub-applications

ELAM landing page with the sub-applications Administration, Assistant and Evaluation

ELAM consists of three sub-applications: Administration, Assistant and Evaluation. In the Administration, the system is configured, devices are created and work instructions are set up. These are then started in the Assistant, which shows the worker's view at the workstation. Finally, the Evaluation presents the production data clearly in statistics.

In the following, we switch back and forth between the functions of the Administration and conclude with the Assistant.

3. Opening the Administration

In the first step, the Administration is opened; this is where the work instruction is created. The following sections describe:

  • Basic elements of the landing page, the central portal of ELAM
  • The Administration and the flowchart editor

This is followed by the creation of the work instruction in ELAM.

3.1 Opening the Administration

Landing page: open the Administration

All ELAM applications can be reached via the landing page. Open the Administration.

Note: The landing page can also be reached from the desktop.

4. Overview: Administration

Overview of the Administration with navigation, profile and language selection
  • The house icon takes you back to the landing page.
  • Here you log profiles in or out and select the language.
  • To create a work instruction, select “Flowcharts” under the “Workflows” tab.
  • Then click “New flowchart”. The flowchart editor opens. It is one of the core functions of ELAM.

Note: In ELAM, work instructions are created in the form of flowcharts.

5. Overview: Flowchart Editor

Overview of the flowchart editor with toolbar and controls

Note: Only released flowcharts can be used at production level.

The most important controls of the flowchart editor:

  • Save and release
  • Flowchart name: A flowchart name must be assigned.
  • Delete flowchart
  • Toolbar: Undo, redo, edit an element and search bar
  • Export flowchart
  • Full-screen mode
  • Screen zoom
  • Settings

5.1 Creating a Flowchart

The following explains how to create a flowchart. A flowchart always begins with a start block and ends with an end block. All kinds of elements can be inserted in between.

Dragging elements into the flowchart and connecting them
  1. To add a new element to the flowchart, click and hold the desired element in the column and drag it onto the canvas.
  2. To connect the elements, each side of an element has a green circle. Connect these circles to each other.
  3. First, a basic structure for a work instruction is built. This is described in the following section.

5.2 Creating the Basic Structure

In the following, a flowchart for a vacuum pump is created step by step as an example. First, a basic structure is created. It is important that the flowchart has been given a name.

Basic flowchart structure with eight numbered steps

This basic structure provides a pick step (1), a manual step (2), a question (3+4), screwing steps (5+6) and a question list (7). The last step (8) is a “completion” step.

  • To add a work step in ELAM, drag the TAF function onto the canvas. A TAF can be configured by double-clicking it.
  • A condition is an if-else function that can be configured as desired and is used for branches in the flowchart. In this case, it depends on how the question in the preceding TAF is answered.

5.3 Configuring a TAF

Now the individual TAFs are configured step by step. Double-clicking the first TAF opens the following configuration page. The individual areas are introduced in the next sections.

TAF configuration page (TAF details)

The language selection at the top right can be used to create the work instruction in other languages.

5.4 Configuring a TAF – Pick Step

First, the right-hand side is adapted for the first step. It is configured as a pick step.

Configuring a pick step: TAF type, TAF name, task and signals
  1. “Automatic” is selected as the TAF type. This allows the TAF to be acknowledged via the pick-to-light module.
  2. Under “TAF name”, the name in the flowchart editor is adjusted. “Task” and “Description”, by contrast, are shown in the assistant and are set here. This defines which task the TAF is to perform.
  3. For the signal, in this case the control of the PTL modules, parts must first be created and linked to the modules. This is done later.

5.5 Selecting the Status

Selecting the status “Continue on status”

The different statuses define when the flowchart advances to the next TAF. As long as no selected status has been reached, the current TAF remains active.

Note: The status “Manual OK” (MOK) means that the acknowledgement is released manually. NOK stands for “Not OK”.

5.6 Selecting an Image and Saving

After the description has been defined, an image is uploaded under “Additional type” and the TAF is saved.

Uploading an image and saving the TAF
  1. Switch “Additional type” to “Image”.
  2. Add an image from the PC (left) or add it directly from a mobile phone via a QR code (right). Here the image can be edited if necessary. More details can be found in the Quicksteps.
  3. Click “Save and close”.

Note: To upload a photo via QR code with a mobile device, the device running the ELAM software and the mobile device must be on the same network. Details can be found in the Quickstep “0.5-Quickstep Flowchart”.

5.7 Back to the Flowchart Editor

In the flowchart editor, enter a name and save the flowchart. The flowchart can later be reopened under this name.

Flowchart with the first TAF configured

Note: The TAF is black if the step is automatic.

6. Creating and Configuring Pick-to-Light Displays and a Pick-to-Light Step

The following describes an example procedure for setting up the KBS pick-to-light system in ELAM.

6.1 Creating the Pick-to-Light Controller

To control the pick-to-light modules, the pick-to-light controller must be created as a device.

Creating the pick-to-light controller as a device
  1. In the management area, select “Devices” and click “New device”.
  2. Select “ELAM_Picking_Controller” as the type.
  3. Select a Pic (program identification code), e.g. “ELAM_Picking_Station_01”. If several controllers run on one server at the same time, they can be selected here.
  4. Enter a short name.

Note: After creating the device, the “ELAM_Picking_Controller” service must be restarted so that the compartment displays are created automatically. Alternatively, compartment displays can be set up manually beforehand. This is described in the following section. Restarting services is described in section 13.6.

6.2 Creating Modules (Compartment Displays)

Compartment displays are normally created automatically. If this is not the case, they can also be created manually using the serial number.

Compartment displays (modules) in the management area
  1. In the management area, select “Compartment displays”.
  2. If no compartment displays have been created, they can be created manually here (“New compartment display”).

Note: The type of a compartment display is filled in automatically. Using the serial number, which is also printed on the module, the module can be created and assigned to a controller (device). If the status is green, the module is recognised by the controller. If the status is red, the display is not found.

6.3 Creating Parts

Parts are created here as an example. Parts are assigned to a location, which in turn is linked to the compartment displays.

Creating a part
  1. In the management area, select “Parts”.
  2. Click “New part”.
  3. Enter the part identification and assign a name. The identification is selected in the TAF.

Note: The assignment of locations is described in the next section. Scan codes are optional if the removal of the part is to be additionally secured with a scan.

6.4 Creating and Linking Locations

Locations act as the central link between parts and compartment displays. This section explains the linking.

Creating a location and linking it to a part and a compartment display
  1. Click “Locations”, then “New location”.
  2. Give the location a name.
  3. Assign a part and a compartment display to the location.
  4. Click “Save”.

6.5.1 Adding a Pick-to-Light Signal

So that the TAF can fulfil its function of communicating with the pick-to-light modules, a signal is added. Several signals can also be added to one TAF.

Adding a signal to the TAF and selecting the signal
  1. Add a signal (“+”). The pencil icon can be used to edit a signal.
  2. Select the signal “Part removal – SWA”. In this case, the PTL modules are controlled via the SWA.

Note: When signals are added, TAFs of type “Automatic” can complete on their own, because a signal can confirm that a certain activity has been performed. Some signals are part of the standard scope of the system. Individual signals for processes or tools are created on a customer-specific basis.

6.5.2 Configuring the Pick-to-Light Signal

Clicking the signal opens the following configuration window:

Configuring the signal “Part removal – SWA” and saving the TAF
  1. Select the part. The program is selected automatically.
  2. Click “Save”.
  3. On the TAF configuration page, click “Save and close”.

7. Creating and Configuring a Manual Step

The following configures a manual step in which the lower pump housing is placed. Manual steps are used when it is to be confirmed manually that an activity has been completed, or a note is to be acknowledged manually, but this does not represent a manual OK.

Opening the second TAF in the flowchart editor
  1. In the flowchart editor, click the second TAF to open the configuration menu.

Note: The TAF type can also be recognised by the colour of its border. For example, the automatic PTL step has a black border.

7.1 Creating a Manual Step

Configuring a manual step
  1. Set the TAF type to “Manual”.
  2. Enter the TAF name, task and description.
  3. Add an image.
  4. Save and close.

Note: A manual step does not need a signal.

8. Creating and Configuring a Question Step Including a Condition

The following example explains how a question can be integrated into the workflow using a condition. Conditions allow complex branching to be modelled, because as parsers they can access and evaluate information from the entire product life-cycle record.

A question step is placed before a condition. Within the condition, the possible answers to the question or other if-else outputs are linked to the corresponding follow-up paths.

8.1 Creating / Configuring the Question Step

The question step prepared in the basic structure is now configured.

Selecting the third TAF in the flowchart
  1. Click the third TAF in the flowchart. This step is to become a question step.

8.2 Configuring the Question Step

Configuring the question step
  1. Set the TAF type to “Question”.
  2. Enter the TAF name, task and description.
  3. Add an image.
  4. Activate “Continue on status NOK”.
  5. Save and close.

8.3 Creating / Configuring the Condition

Naming the follow-up TAFs and opening the condition
  1. Name the follow-up TAFs.
  2. Double-click the condition to configure it.

8.4 Configuring the Condition

This section shows how to configure a condition for a question.

Configuring a condition for a question
  1. Give the condition a name.
  2. The XPath defines the location in the product life-cycle record that is checked by the condition. The path for questions is the default setting.
  3. Enter the XPath result value: 1 stands for “yes”, 3 stands for “no”, and else must always be assigned. (“else” can replace 1 or 3 here, but can also be added in addition by dragging out another path.)
  4. If desired, add a description.
  5. Save.

Note: For each path dragged out of the condition, there is an option under “Target” that is named like the TAF that follows.

9. Creating a Screwdriver as a Device

The following uses the example of an Open Protocol screwdriver to show how to set up a screwdriver. In general, ELAM controls the programs set in the screwing system and transfers result values back. This means that the screwing program settings are made individually in the screwing system. The configuration depends on the ELAM controller used.

9.1 Creating an Open Protocol Screwdriver as a Device

To control a screwdriver, a device must first be created.

Creating an Open Protocol screwdriver as a device
  1. In the management area, select “Devices” and click “New device”.
  2. Select “ELAM_Picking_Controller” as the type.
  3. Select “ELAM_OpenProtocol_Controller” as the Pic (program identification code).
  4. Enter a short name.
  5. Enter the IP address of the screwdriver. Port 4545 is preset.

Note: The IP address and screwing programs are set in the screwdriver.

9.2 Releasing the Open Protocol Screwdriver

After a new device has been created, it must still be saved and released.

Saving the device and releasing the configuration
  1. Save.
  2. Release the configuration to use the screwdriver in the process.

10. Creating Screwing Steps

There are two ways to create screwing steps in ELAM:

  1. Signal in the TAF: This is a normal TAF with the signal that enables and locks the screwdriver and activates data transfer.
  2. Process display (PZA): The process display highlights the screwing points or process points in a defined sequence.

10.1 Screwing Step as a Signal in the TAF

To configure the screwing step as a signal, the flowchart with the basic structure is opened again.

Opening the right-hand TAF of the flowchart
  1. Double-click the right-hand TAF in which the signal is to be configured.

10.2 Configuring the Screwing Step

In the next step, an image, the task and the description are added. In addition, the TAF is set to “Automatic”.

Configuring the screwing step
  1. Set the TAF to “Automatic”.
  2. Enter the task and description.

The image can be edited here if necessary. More details can be found in the Quicksteps.

10.3 Selecting the Signal

Now the signal for the Open Protocol screwdriver is selected in order to communicate with it.

Selecting the signal “OpenProtocol – enable pset”
  1. Add a signal.
  2. Select the signal “OpenProtocol – enable pset”.

10.4 Configuring the Signal and Saving the TAF

Clicking the signal opens the following configuration window:

Configuring the signal: target and PSet
  1. Select the device you created as the target.
  2. Select the PSet to be used for the screwing operation.
  3. Click “Save”.
  4. On the TAF configuration page, click “Save and close”.

10.5 Creating a PZA

The following describes how process displays are created in ELAM. First, the end signal is added.

Creating a process display and adding the end signal
  1. In the management area, open the “Process displays” menu, then click “New process display”.
  2. Enter a name.
  3. Select an image.
  4. Add a signal and click “End”.
  5. Select the signal “PZA OpenProtocol – disable” and select the OpenProtocol screwdriver as the target.

10.6 Adding Process Points

In this step, the process points are added. They make a sequence visible and are marked in the image. The red circles in the image do not represent the process points.

Adding process points and creating markings in the image
  1. Click “Process points”.
  2. Click “Add process point”.
  3. Expand the process point.
  4. Create a marking and edit and move it in the image.
  5. Add a signal: click “Incoming”, then select the signal “PZA OpenProtocol – enable pset” and select the tool “OpenProtocol screwdriver” as the target.

Note: This step is repeated for as many process points as required. In this case, 3 process points are added using the same procedure. Process points can also be copied.

10.7.1 Saving and Releasing the PZA

To be able to use the PZA, it must be saved and released.

Saving and releasing the process display
  1. Save and release the PZA.
  2. After saving, switch back to the flowchart editor and open the TAF in which the process display is to be shown.

Note: No description needs to be entered in the TAF, as the process display overlays it in the assistant. More on this in the section “Performing the work steps”.

10.7.2 Selecting the Signal “Process display – View” in the TAF

In this step, the TAF is configured so that the PZA is controlled via the signal “Process display – View”.

Configuring the signal “Process display – View”
  1. Back in the TAF for the PZA, select the signal “Process display – View”.
  2. Select the process display you created as the header.
  3. Select the desired PSet or job.
  4. Select the OpenProtocol screwdriver as the device.
  5. Save.
  6. Save and close the TAF.

11. Creating and Using Question Lists

To display a question list in the work instruction, questions are first created and then assigned to an inspection plan, which can be addressed as a signal in the TAF. The procedure is described below.

11.1 Creating Questions

In the “Question lists” tab, questions and lists can be created and adapted across the system.

Question lists overview
  1. Click “Question lists”.
  2. Add a question.

11.2 Configuring Questions

The following window opens when you create a question:

Creating a question with answers
  1. Add a question. Optionally, a second question can be added as a negation of the first question.
  2. Add answers and specify which answer is correct.
  3. Apply.

Optionally, an image can be added.

Note: If available, the second question is asked at random to prevent “clicking through”. The answers are also shuffled randomly but remain correctly linked in the system.

11.3 Creating an Inspection Plan and Assigning Questions

The inspection plan consists of any number of questions. They are simply added to the inspection plan by drag and drop.

Creating an inspection plan and assigning questions by drag and drop
  1. Click “Inspection plans”.
  2. Add a new inspection plan.
  3. Enter a name.
  4. Drag the questions (“measuring points”) from right to left to add them to the inspection plan.
  5. Save and release.

11.4 Selecting the Signal in the TAF

Back in the TAF configuration for the second-to-last step, the signal “Question lists – View” is now selected. The following window opens:

Configuring the signal “Question lists – View” with an inspection plan
  1. Select the inspection plan.
  2. Save.

12. Completing a Work Instruction

The “Completion” TAF defines which status the product has before the end of the work instruction when this branch is run through. For this, the signal “Completion – Flowchart” is used with the status “OK”:

Signal “Completion – Flowchart” with status OK

13. Final Steps

To use the flowchart in the assistant, it must be released and assigned to a variant. This process is described in the following sections. The work instruction can then be displayed in the assistant.

To ensure that all devices work correctly, the most important ELAM controllers are restarted in the Windows services.

13.1 Saving and Releasing the Flowchart

In this step, the flowchart is saved and released.

Saving and releasing the flowchart
  1. Save the flowchart.
  2. Release the flowchart.

13.2 Creating a Variant under Master Data

Creating a new variant under master data
  1. Under “Product management”, click “Master data”.
  2. Under “New master data”, click “New variant”.

13.3 Configuring the Variant

Configuring the variant: variant number, short name, scan code
  1. Add a variant number.
  2. Enter a short name.
  3. Save.

With a scan code (regular expression), the variant can be started directly by a scan.

Note: Variants can also be imported from the ERP system, or started in a defined sequence via orders (e.g.) from the ERP system.

13.4 Opening Assignments

Assignments: selecting the variant
  1. Under “Workflows”, click the “Assignments” tab.
  2. Click the variant you created earlier.

13.5 Linking the Variant and Flowchart via “Assignments”

Assigning the flowchart, stations and period of use
  1. Assign the flowchart.
  2. Assign the stations at which this variant is to be started or may be started.
  3. Define the period of use. “Valid from” is preset and “Valid until” is optional.
  4. Apply and save.

13.6 Restarting the ELAM Services

To ensure the controllers work correctly, it is recommended to restart them. To do this, open the services in Windows (search for “Services” in the Windows search).

Windows services: starting or restarting ELAM services
  1. Select the ELAM service(s).
  2. Start the ELAM service(s) (left) or restart them (right).

14. Checking the Workflow in the Assistant

After the work instruction has been created and linked to a variant, it can be started or clocked in in the assistant. Without central order control, variants can be started in the assistant depending on the assigned rights. The following shows what the created work instruction looks like in the assistant and what the user should pay attention to.

14.1 Starting the Assistant

This is how you get from the Administration to the Assistant: first click the house icon to return to the landing page.

Back to the landing page

Then open the Assistant.

Landing page: open the Assistant

Note: The landing page can also be reached from the desktop.

14.2 Assistant: Start Form and Starting the Variant

When the assistant is opened, the start form is shown first. The basic functions are explained below.

Assistant: start form
  • User, order, serial number and variant can be entered manually or automatically.
  • Orders/variants can be started manually via the “Start” button or automatically (for example by scan).
  • Orders that have already been started but not finished can be viewed and continued here.
  • In the configuration, settings for the start form can be made.

Now the variant you created, and with it the work instruction, is started.

Selecting and starting the variant
  1. Select the variant.
  2. Start the variant.

This is the simplest configuration variant, which is selected by default.

14.3 Performing the Work Steps

Pick-to-light step: This is what the pick-to-light step looks like in ELAM.

Pick-to-light step in the assistant with controls
  • Image, description text and production data are shown in the work step.
  • Controls: one step forward, navigation, full screen, comment entry, repeat step, repeat block, pause process, configuration menu, one step back.
  • With “Manual OK”, a comment must be left.

Manual step and question step: This is what the manual step and the question step look like in ELAM.

Manual step and question step in the assistant
  • The manual step is acknowledged manually.
  • The question is answered using the “Yes” and “No” buttons.

Process display: This is what the process display looks like in ELAM. If no process display is used, the screwing step looks like the pick-to-light step.

Process display in the assistant
  • The image in the process display is dynamic and, in this case, highlights the location of the screwing operation.
  • The process values can be viewed on the right-hand side.

Question list: The last step is the question list.

Question list in the assistant

The questions must be answered before the step can be confirmed with “Apply”. After this step is completed, the instruction is closed automatically and the system returns to the start form of the assistant.

Get in touch with us

Do you have any questions about our company or our worker assistance system? Would you like to find out more about our ELAM system or get a test account directly? Would you like a free consultation for your company? Write to us and we will get back to you as soon as possible.
‍
Our products and services are only available to commercial customers.
Thank you! Your submission has been received!
Oops! Something went wrong while submitting the form.